“Device modularity” and “smaller dimensions” are two of the most important criteria when selecting a frequency inverter for
a specific application. SEW‑EURODRIVE is aware of these requirements and, as a result, has designed a compact and economic
solution with its target-specific development of the MC07 series: MOVITRAC® MC07B – the next generation frequency inverter.
a specific application. SEW‑EURODRIVE is aware of these requirements and, as a result, has designed a compact and economic
solution with its target-specific development of the MC07 series: MOVITRAC® MC07B – the next generation frequency inverter.
Your advantages:
- High-quality system components
- High power range across all supply voltage ranges
- High EMC protection
- Simple operation and startup
- Excellent price/performance ratio
|
MOVITRAC® MC07B
|
|
Line connection
|
Power range
|
|
200/240 V / 1-phase
|
0.25 – 2.2 kW
|
|
200/240 V / 3-phase
|
0.25 – 30 kW
|
|
400/500 V / 3-phase
|
0.25 – 75 kW
|
Device variant:
|
Standard
|
Technology (application module)
|
---|---|---|
Continuous motion/processing
|
||
Crushers
|
Yes
|
Yes
|
Conveyor belts
|
Yes
|
Yes
|
Chain conveyors
|
Yes
|
Yes
|
Fan
|
Yes
|
Yes
|
Pumps
|
Yes
|
Yes
|
Roller conveyors
|
Yes
|
Yes
|
Extruders
|
Yes
|
Yes
|
Mixers
|
Yes
|
Yes
|
Escalators
|
Yes
|
Yes
|
Centrifuges
|
Yes
|
Yes
|
Simple positioning (replaces rapid/creep speed switch-over with initiator evaluation)
|
||
Dosing pumps
|
No
|
Yes
|
Rotary tables
|
limited
|
Yes
|
Trolleys
|
limited
|
Yes
|
Hoists
|
limited
|
Yes
|
Cranes
|
limited
|
Yes
|
Transverse carriages
|
limited
|
Yes
|
Dynamic positioning
|
||
Dosing pumps
|
No
|
No
|
Handling systems
|
No
|
No
|
Motion control axes
|
No
|
No
|
SRS
|
No
|
No
|
Device variant:
|
Standard
|
Technology (application module)
|
---|---|---|
Line voltages
|
||
1 x AC 200 – 240 V (50/60 Hz)
|
Yes
|
Yes
|
2 x AC 200 – 240 V (50/60 Hz)
|
Yes
|
Yes
|
3 x AC 380 – 500 V (50/60 Hz)
|
Yes
|
Yes
|
Line types
|
||
IT
|
Yes
|
Yes
|
TN with directly grounded star point
|
Yes
|
Yes
|
TT with directly grounded star point
|
Yes
|
Yes
|
Control modes
|
||
Voltage/frequency control V/f
|
Yes
|
Yes
|
Voltage-controlled vector control VFC
|
Yes
|
Yes
|
Current-controlled vector control CFC
|
No
|
No
|
Functions
|
||
Speed synchronization
|
Yes
|
Yes
|
Simple positioning
|
No
|
Yes
|
Flying start function
|
Yes
|
Yes
|
Free programming (IPOSplus)
|
Yes
|
Yes
|
DC braking
|
Yes
|
Yes
|
Lifting function
|
Yes
|
Yes
|
Torque control
|
No
|
No
|
Energy efficiency
|
||
Energy saving function
|
Yes
|
Yes
|
DC link coupling
|
limited
|
limited
|
Regenerative power supply
|
limited
|
limited
|
Functional safety
|
||
PROFIsafe
|
Optional
|
Optional
|
STO
|
Yes
|
Yes
|
SS1
|
limited
|
limited
|
Communication types
|
||
CANopen
|
Yes
|
Yes
|
DeviceNet
|
Optional
|
Optional
|
EtherCAT
|
Optional
|
Optional
|
Ethernet/IP
|
Optional
|
Optional
|
Modbus TCP
|
Optional
|
Optional
|
PROFIBUS DPV1
|
Optional
|
Optional
|
PROFINET IO
|
Optional
|
Optional
|
Motor types
|
||
Asynchronous motors
|
Yes
|
Yes
|
High-frequency motors
|
Yes
|
Yes
|
LSPM motors
|
Yes
|
Yes
|
Motors in potentially explosive atmospheres
|
Yes
|
Yes
|
Servomotors
|
No
|
No
|
Synchronous motors
|
No
|
No
|
Encoder types
|
||
Absolute encoder
|
No
|
No
|
Incremental encoder
|
No
|
No
|
Resolver
|
No
|
No
|
SEW built-in encoders
|
No
|
Yes
|
Certifications
|
||
CE
|
Yes
|
Yes
|
cUL
|
Yes
|
Yes
|
UL
|
Yes
|
Yes
|
C-Tick
|
Yes
|
Yes
|
Options
|
|
FBG11B
|
Pluggable basic keypad
|
UBP11A
|
Parameter module
|
DBG60B
|
Plain text keypad
|
FSC11B / FSC12B / FSE24B
|
Communication module for connecting MOVITRAC® MC07B via SBus/RS-485 / EtherCAT® for diagnostics and parameter setting via PC
|
FIO11B
|
Analog module with setpoint input, analog output and RS-485 interface
|
FIO21B
|
Digital module with 7 digital inputs and SBus connection
|
MBG11A
|
Setpoint adjuster
|
DFP21B / DFE24B / DFE32B / DFE33B / DFD11B
|
Fieldbus gateways either integrated or in separate housings: PROFIBUS DP-V1 / EtherCAT® / PROFINET IO / EtherNet/IP and Modbus TCP / DeviceNet (CANopen integrated in the basic unit)
|
UWS11A / UWS21B / USB11A
|
Interface adapter
|
MOVI-PLC®
|
Motion control programmable in IEC 61331 with powerful libraries
|
Technology version with IPOSplus® programming and simple positioning application module.
|
|
SafetyDRIVE: Integrated functional safety
Safe Torque Off (STO) standard version up to performance level (PL) d according to EN ISO 13849-1 for 3 × AC 230 V / 400 V units from 0.55 kW to 75 kW (optionally 230 V to 2.2 kW, and 400 V up to 4 kW). |
Accessories and options
|
|
MOVITOOLS® MotionStudio engineering software
|
The MOVITOOLS® MotionStudio program package allows you to conveniently start up and set parameters for MOVITRAC® MC07B frequency inverters and MOVIDRIVE® MDX60/61B inverters.
|
MDR60A regenerative power supply unit
|
The MDR60A regenerative power supply can supply multiple units with power using a central power supply connection. In regenerative mode, the power is fed back into the supply system. Using MDR60A lets you save power and installation costs. |
Braking resistor type BW
|
BW series braking resistors are available for operating MOVITRAC® MC07B and MOVIDRIVE® MDX60/61B inverters as generators. Using an integrated temperature sensor, the resistor can be protected without external monitoring. |
Line choke type ND
|
ND series line chokes increase the overvoltage protection of inverters. This is an important characteristic in rough industrial power supply systems, especially if the inverter is installed near a supply transformer. |
Line filter type NF
|
NF type line filters are available for EMC compliant installation as specified by EN 55011. They suppress interference emissions on the line side of inverters. These line filters ensure that limit value class B is maintained on the supply end. |
Output choke type HD
|
HD series output chokes suppress interference emitted from unshielded motor cables. They enable the motor to meet limit value class B requirements in accordance with EN 55011 in EMC-compliant installations. Output chokes provide an alternative to shielded motor cables in EMC-compliant installations. |
Output filter type HF
|
HF series output filters are sine filters that smooth out the output voltage of inverters. Output filters are used for group drives to suppress discharge currents in motor cables and for long motor cables to prevent voltage peaks. |
back to top |